65W Single Output Medical Type
Features
3″x2″ compact size
Universal AC input / Full range
Class 2(without FG) installations
Medical safety approved(2 x MOPP between primary to secondary)
Suitable for BF application with appropriate system consideration
Low leakage current < 100A
No load power consumption < 0.1W
High efficiency up to 91%
For 1U applications
Protections: Short circuit/ Overload / Over Voltage
Cooling by free air convection
-30~70C wide range of operating temperature
Operating altitude up to 4000 meters
LED indicator for power on
3-year warranty
RPS-65 series
MODEL | RPS-65-3.3 | RPS-65-5 | RPS-65-7.5 | RPS-65-12 | |
---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 3.3V | 5V | 7.5V | 12V |
RATED CURRENT | 10A | 10A | 8A | 5.42A | |
CURRENT RANGE | 0 ~ 11A | 0 ~ 11A | 0 ~ 8.8A | 0 ~ 5.96A | |
RATED POWER | 33W | 50W | 60W | 65W | |
PEAK LOAD(10sec.) | 36 3W | 55W | 66W | 71.5W | |
RIPPLE & NOISE (max.) | 80mVp-p | 80mVp-p | 80mVp-p | 120mVp-p | |
VOLTAGE ADJ. RANGE | 2.9~3.6V | 4.7~5.5 | 7.12~8.3V | 11.4~13.2V | |
VOLTAGE TOLERANCE | ± 2.0% | ± 2.0% | ± 2.0% | ± 2.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ± 2.0% | ± 2.0% | ± 2.0% | ± 2.0% | |
SETUP, RISE TIME | 500ms, 30ms / 230VAC 500ms, 30ms / 115VAC at full load | ||||
HOLD UP TIME (Typ.) | 30ms / 230VAC 12ms / 115VAC at full load | ||||
INPUT | VOLTAGE RANGE | 80 ~ 264VAC | |||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
EFFICIENCY(Typ.) | 80% | 84% | 85% | 88% | |
AC CURRENT (Typ.) | 1.5A/ 115VAC 1A/ 230VAC | ||||
INRUSH CURRENT (Typ.) | СOLD STAR 30A/115VAC 50A/230VAC | ||||
LEAKAGE CURRENT(max.) | Touch current< 100 A/264VAC | ||||
Specs Sheet | Download PDF |
RPS-65 series
MODEL | RPS-65-15 | RPS-65-24 | RPS-65-48 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 15V | 24V | 48V |
RATED CURRENT | 4.34A | 2.71A | 1.36A | |
CURRENT RANGE | 0 ~ 4.77A | 0 ~ 2.98A | 0 ~ 1.49A | |
RATED POWER | 65.1W | 65W | 65.3W | |
PEAK LOAD(10sec.) | 71.6W | 71.5W | 71.5W | |
RIPPLE & NOISE (max.) | 150mVp-p | 240mVp-p | 300mVp-p | |
VOLTAGE ADJ. RANGE | 13.5~16.5V | 22.8~27.6V | 45.6~52.8V | |
VOLTAGE TOLERANCE | ± 1.0% | ± 1.0% | ± 1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ± 1.0% | ± 1.0% | ± 1.0% | |
SETUP, RISE TIME | 500ms, 30ms / 230VAC 500ms, 30ms / 115VAC at full load | |||
HOLD UP TIME (Typ.) | 30ms / 230VAC 12ms / 115VAC at full load | |||
INPUT | VOLTAGE RANGE | 80 ~ 264VAC | ||
FREQUENCY RANGE | 47 ~ 63Hz | |||
EFFICIENCY(Typ.) | 89% | 90% | 91% | |
AC CURRENT (Typ.) | 1.5A/ 115VAC 1A/ 230VAC | |||
INRUSH CURRENT (Typ.) | СOLD STAR 30A/115VAC 50A/230VAC | |||
LEAKAGE CURRENT(max.) | Touch current< 100 A/264VAC | |||
Specs Sheet | Download PDF |