GSM60A series
60W AC-DC Reliable Green Medical Adaptor
Features
3 pole AC inlet IEC320-C14, Class 1 power unit
Medical safety approved(2 x MOPP) according to ANSI/AAMI ES60601-1 and IEC/ENC60601-1
Extremely low leakage current
No load power consumption < 0.1W
Energy efficiency level VI and meet CoC version (Except 5~9V for level V)
-30~+70C wide range working temperature
Protections: Short circuit / Overload / Over voltage / Over temperature
LED indicator for power on
Lifetime > 105 K hours
3-year warranty
GSM60A series
ORDER NO. | GSM60A05-P1J | GSM60A07-P1J | GSM60A09-P1J | GSM60A12-P1J | |
---|---|---|---|---|---|
OUTPUT | SAFETY MODEL NO. | GSM60A05 | GSM60A07 | GSM60A09 | GSM60A12 |
DC VOLTAGE | 5V | 7.5V | 9V | 12V | |
RATED CURRENT | 6A | 6A | 6A | 5A | |
CURRENT RANGE | 0.1 ~ 6A | 0.1 ~ 6A | 0.1 ~ 6A | 0.1 ~ 5A | |
RATED POWER (max.) | 30W | 45W | 54W | 60W | |
RIPPLE & NOISE (max.) | 80mVp-p | 80mVp-p | 100mVp-p | 100mVp-p | |
VOLTAGE TOLERANCE | ±5.0% | ±5.0% | ±5.0% | ±3.0% | |
LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LOAD REGULATION | ±5.0% | ±5.0% | ±5.0% | ±3.0% | |
SETUP, RISE TIME | 1000ms, 30ms / 230VAC 1500ms, 30ms / 115VAC at full load | ||||
HOLD UP TIME (Typ.) | 50ms / 230VAC 18ms / 115VAC at full load | ||||
INPUT | VOLTAGE RANGE | 80 ~ 264VAC 113 ~ 370VDC | |||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
EFFICIENCY (Typ.) | 81.5% | 86% | 87.5% | 88% | |
AC CURRENT (Typ.) | 1.4A/ 115VAC 1A/ 230VAC | ||||
INRUSH CURRENT (Typ.) | Cold start 30A/115VAC 60A/ 230VAC | ||||
LEAKAGE CURRENT(max.) | Earth leakage current < 100 A/264VAC , Touch current < 100 A/264VAC | ||||
Specs | Download PDF |
GSM60A series
ORDER NO. | GSM60A15-P1J | GSM60A18-P1J | GSM60A24-P1J | GSM60A48-P1J | |
---|---|---|---|---|---|
OUTPUT | SAFETY MODEL NO. | GSM60A15 | GSM60A18 | GSM60A24 | GSM60A48 |
DC VOLTAGE | 15V | 18V | 24V | 48V | |
RATED CURRENT | 4A | 3.33A | 2.5A | 1.25A | |
CURRENT RANGE | 0.1 ~ 4A | 0.1 ~ 3.33A | 0.1 ~ 2.5A | 0.1 ~ 1.25A | |
RATED POWER (max.) | 60W | 60W | 60W | 60W | |
RIPPLE & NOISE (max.) | 100mVp-p | 120mVp-p | 150mVp-p | 240mVp-p | |
VOLTAGE TOLERANCE | ±3.0% | ±3.0% | ±3.0% | ±2.5% | |
LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LOAD REGULATION | ±3.0% | ±3.0% | ±3.0% | ±3.0% | |
SETUP, RISE TIME | 1000ms, 30ms / 230VAC 1500ms, 30ms / 115VAC at full load | ||||
HOLD UP TIME (Typ.) | 50ms / 230VAC 18ms / 115VAC at full load | ||||
INPUT | VOLTAGE RANGE | 80 ~ 264VAC 113 ~ 370VDC | |||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
EFFICIENCY (Typ.) | 88.5% | 89% | 90.5% | 91.5% | |
AC CURRENT (Typ.) | 1.4A/ 115VAC 1A/ 230VAC | ||||
INRUSH CURRENT (Typ.) | Cold start 30A/115VAC 60A/ 230VAC | ||||
LEAKAGE CURRENT(max.) | Earth leakage current < 100 A/264VAC , Touch current < 100 A/264VAC | ||||