RPS-75 series
75W Reliable Green Medical Power Supply
Features
5″x2″ compact size
Medical safety approved(2 x MOPP) according to ANSI/AAMI ES60601-1 and IEC/EN60601-1
Suitable for BF application with appropriate system consideration
75W convection, 100W force air
EMI Class B for Class 1 configuration
No load power consumption <0.75W
Remote sense function
Protections: Short circuit/ Overload / Over Voltage
Lifetime > 80K hours
3-year warranty
RPS-75 series
MODEL | RPS-75-3.3 | RPS-75-5 | RPS-75-12 | RPS-75-15 | |
---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 3.3V | 5V | 12V | 15V |
RATED CURRENT | 15A | 14A | 6.3A | 5A | |
CURRENT RANGE | 0 ~ 20A | 0 ~ 18.7A | 0 ~ 8.3A | 0 ~ 6.7A | |
RATED POWER | 49.5W | 70W | 75.6W | 75W | |
PEAK LOAD (23.5CFM) | 66W | 93.5W | 99.6W | 100.5W | |
RIPPLE & NOISE (max.) | 60mVp-p | 60mVp-p | 60mVp-p | 60mVp-p | |
VOLTAGE ADJ. RANGE | 2.9 ~ 3.6V | 4.75 ~ 5.5V | 11.4 ~ 13.2V | 13.5 ~ 16.5V | |
VOLTAGE TOLERANCE | ±2.0% | ±2.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.5% | ±1.5% | ±1.0% | ±1.0% | |
SETUP, RISE TIME | 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load | ||||
HOLD UP TIME (Typ.) | 90ms/230VAC 20ms/115VAC at full load | ||||
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~370VDC | |||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
EFFICIENCY(Typ.) | 73% | 78% | 82% | 83% | |
AC CURRENT (Typ.) | 1.5A/115VAC 1A/230VAC | ||||
INRUSH CURRENT (Typ.) | COLD START 25A/115VAC 50A/230VAC | ||||
LEAKAGE CURRENT(max.) | Earth leakage current < 150 A/264VAC , Touch current < 100 A/264VAC | ||||
Specs Sheet | Download PDF |
RPS-75 series
MODEL | RPS-75-24 | RPS-75-36 | RPS-75-48 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 24V | 36V | 48V |
RATED CURRENT | 3.2A | 2.1A | 1.6A | |
CURRENT RANGE | 0 ~ 4.2A | 0 ~ 2.8A | 0 ~ 2.1A | |
RATED POWER | 76.8W | 75.6W | 76.8W | |
PEAK LOAD (23.5CFM) | 100.8W | 100.8W | 100.8W | |
RIPPLE & NOISE (max.) | 100mVp-p | 100mVp-p | 100mVp-p | |
VOLTAGE ADJ. RANGE | 22.8 ~ 27.6V | 34.2 ~ 39.6V | 45.6 ~ 52.8V | |
VOLTAGE TOLERANCE | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | |
SETUP, RISE TIME | 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load | |||
HOLD UP TIME (Typ.) | 90ms/230VAC 20ms/115VAC at full load | |||
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~370VDC | ||
FREQUENCY RANGE | 47 ~ 63Hz | |||
EFFICIENCY(Typ.) | 85% | 86% | 86% | |
AC CURRENT (Typ.) | 1.5A/115VAC 1A/230VAC | |||
INRUSH CURRENT (Typ.) | COLD START 25A/115VAC 50A/230VAC | |||
LEAKAGE CURRENT(max.) | Earth leakage current < 150 A/264VAC , Touch current < 100 A/264VAC | |||
Specs Sheet | Download PDF |