OWA-120U series

120W Single Output Moistureproof Adaptor

 Features

 Universal AC input/Full range
 Class II power unit, no FG
 Built in active PFC function
 High efficiency up to 90.5%
 No load power consumption < 0.15W
 Energy efficiency Level VI
 Comply with EISA 2007 DoE and NRCan
 Fully isolated plastic case
 Fanless design, cooling by free air convection
 Protections: Short circuit/ Overload / Over Voltage / Over Temperature
 UL LISTED, suitable for dry and damp locations
 5-year warranty

OWA 120U series

MODELOWA-120U-12 OWA-120U-15OWA-120U-20
OUTPUTDC VOLTAGE12V15V20V
CONSTANT CURRENT REGION7.2 ~ 12V 9 ~ 15V12 ~ 20V
RATED CURRENT10A8A6A
RATED POWER120W120W120W
RIPPLE & NOISE (max.) 150mVp-p150mVp-p150mVp-p
VOLTAGE TOLERANCE±4.0%±4.0%±4.0%
LINE REGULATION±0.5%±0.5%±0.5%
LOAD REGULATION±2.0%±1.5%±1.0%
SETUP TIME500ms, 80ms at 95% load 230VAC / 115VAC
HOLD UP TIME (Typ.)16ms at full load 230VAC / 115VAC
INPUTVOLTAGE RANGE90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE47 ~ 63Hz
POWER FACTOR (Typ.)PF>0.97/115VAC, PF>0.96/230VAC at full load
TOTALHARMONIC DISTORTIONTHD< 20% when output loading>= 60% at 115VAC/230VAC
EFFICIENCY (Typ.) - 115VAC87%88%89%
EFFICIENCY (Typ.) - 230VAC87.5%89%90%
AC CURRENT1.3A / 115VAC 0.65A / 230VAC
INRUSH CURRENT(Typ.) - 30ACOLD START 30A(twidth=520 s measured at 50% Ipeak) at 115VAC
INRUSH CURRENT(Typ.) - 60ACOLD START 60A(twidth=520 s measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.125mA/ 120VAC <0.25mA/ 240VAC
Specs Sheetuntitled-3Download PDF

OWA 120U series

MODELOWA-120U-24OWA-120U-30OWA-120U-36

OUTPUT

DC VOLTAGE24V30V36V
CONSTANT CURRENT REGION14.4 ~ 24V18 ~ 30V21.6 ~ 36V
RATED CURRENT5A4A 3.4A
RATED POWER120W120W122.4W
RIPPLE & NOISE (max.) 150mVp-p200mVp-p 200mVp-p
VOLTAGE TOLERANCE±3.0%±3.0%±2.0%
LINE REGULATION±0.5%±0.5%±0.5%
LOAD REGULATION±0.5%±0.5%±0.5%
SETUP TIME500ms, 80ms at 95% load 230VAC / 115VAC
HOLD UP TIME (Typ.)16ms at full load 230VAC / 115VAC

INPUT

VOLTAGE RANGE90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE47 ~ 63Hz
POWER FACTOR (Typ.)PF>0.97/115VAC, PF>0.96/230VAC at full load
TOTALHARMONIC DISTORTIONTHD< 20% when output loading>= 60% at 115VAC/230VAC
EFFICIENCY (Typ.) - 115VAC89.5%87%88%
EFFICIENCY (Typ.) - 230VAC90.5%87.5%89%
AC CURRENT1.3A / 115VAC 0.65A / 230VAC
INRUSH CURRENT(Typ.) - 30ACOLD START 30A(twidth=520 s measured at 50% Ipeak) at 115VAC
INRUSH CURRENT(Typ.) - 60ACOLD START 60A(twidth=520 s measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.125mA/ 120VAC <0.25mA/ 240VAC
Specs Sheetuntitled-3Download PDF

OWA 120U series

MODELOWA-120U-42OWA-120U-48OWA-120U-54

OUTPUT

DC VOLTAGE42V48V54V
CONSTANT CURRENT REGION25.2 ~ 42V28.8 ~ 48V32.4 ~ 54V
RATED CURRENT2.9A 2.5A 2.3A
RATED POWER121.8W120W124.2W
RIPPLE & NOISE (max.) 250mVp-p 250mVp-p 350mVp-p
VOLTAGE TOLERANCE±1.0%±1.0%±1.0%
LINE REGULATION±0.5%±0.5%±0.5%
LOAD REGULATION±0.5%±0.5%±0.5%
SETUP TIME500ms, 80ms at 95% load 230VAC / 115VAC
HOLD UP TIME (Typ.)16ms at full load 230VAC / 115VAC

INPUT

VOLTAGE RANGE90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE47 ~ 63Hz
POWER FACTOR (Typ.)PF>0.97/115VAC, PF>0.96/230VAC at full load
TOTALHARMONIC DISTORTIONTHD< 20% when output loading>= 60% at 115VAC/230VAC
EFFICIENCY (Typ.) - 115VAC89%89.5%89.5%
EFFICIENCY (Typ.) - 230VAC90%90.5%90.5%
AC CURRENT1.3A / 115VAC 0.65A / 230VAC
INRUSH CURRENT(Typ.) - 30ACOLD START 30A(twidth=520 s measured at 50% Ipeak) at 115VAC
INRUSH CURRENT(Typ.) - 60ACOLD START 60A(twidth=520 s measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.125mA/ 120VAC <0.25mA/ 240VAC
Specs Sheetuntitled-3Download PDF